Validation · Washer-disinfectors

Validation of washer-disinfectors (WD)

We validate and qualify your washer-disinfectors and prove that your cleaning and disinfection processes work reliably and reproducibly under defined conditions – manufacturer-independent, in compliance with standards and traceably documented.

  • SN EN ISO 15883-1
  • SN EN ISO 15883-2
  • ISO/TS 15883-5
  • Guidelines CH, DGKH, DGSV, AKI
  • GPA
  • MedDO (SR 812.213)

Purpose

No safe sterilisation without validated cleaning

Only a clean medical device can be reliably disinfected and sterilised. We test every programme with your load: cleaning with test instruments and actually soiled instruments (residual protein), thermal disinfection via the A0 value.

Where your team cleans and disinfects manually, we assess and validate these procedures under practical conditions – as a sound basis for your work instructions and training.

Typical test objects

  • WDs for surgical and MIS instruments
  • WDs for anaesthesia accessories and containers
  • Manual cleaning and disinfection procedures of your team
  • Drying systems for reprocessed medical devices

Scope of validation

Installation, operational and performance qualification

Validation is divided into three successive stages. During requalification, the performance qualification is repeated periodically or after relevant changes.

IQ

Installation qualification

Installation and media connections according to specification plus proof of water quality (annual analysis).

OQ

Operational qualification

Measuring equipment, door interlock, fault indicators, air filter, self-disinfection, chamber dryness, leak tightness and process sequence.

PQ

Performance qualification

Per programme: thermal disinfection (A0 value) with data loggers, cleaning with test and real instruments, dryness and process residues (conductivity).

What you receive

Complete, traceable documentation – as the basis for your release, internal audits and official inspections.

  • Validation plan with defined tests and acceptance criteria
  • Measurement records, data logger curves and laboratory reports
  • Assessment of the results with traceable justification
  • Validation report with release of the tested programmes
  • Routine test device and date of the next validation

Standards & basis

Standards-compliant and in line with Swiss requirements

We follow the applicable standards, guidelines and regulatory requirements – and document what each assessment is based on.

SN EN ISO 15883-1Washer-disinfectors – general requirements and test methods
SN EN ISO 15883-2WDs with thermal disinfection for surgical instruments, anaesthetic equipment, containers and utensils
ISO/TS 15883-5Test soils and methods for proving cleaning efficacy
Guidelines CH, DGKH, DGSV, AKIValidation and routine monitoring of automated cleaning and thermal disinfection processes
GPA«Good Practice for the Reprocessing of Medical Devices» (Swissmedic) – Swiss reference for reprocessing
MedDO (SR 812.213)Medical Devices Ordinance – maintenance and reprocessing of medical devices

Procedure

How we proceed

  1. Enquiry & inventory

    We record your equipment, programmes and general conditions and clarify the scope of service.

  2. Validation plan

    Programmes, reference loads, tests and acceptance criteria are defined with you.

  3. On-site execution

    Testing with calibrated measuring equipment; samples are evaluated in the laboratory.

  4. Assessment

    The measurement results are compared with the requirements and standards and professionally assessed.

  5. Report & release

    Validation report with release, recommendations and date of the next validation.

For routine monitoring

Suitable products from our online shop

Between validations, you safeguard your process with suitable indicators, test kits and devices.

All products

Frequently asked questions

Good to know

When is validation required?

Before commissioning, after relevant changes to the device, programmes or process chemicals and periodically after 6, 9 or 12 months. Initial validation: each programme three times; requalification: at least one load per programme with the most difficult load configuration.

What is the difference between validation and maintenance?

Maintenance ensures the technical function of the device. Validation proves that the entire process – including programme, chemicals and load – reproducibly achieves the required result.

Do you validate devices from all manufacturers?

Yes. We work independently of manufacturers and validate devices of various makes.

How do we safeguard the process between validations?

With routine checks, for example a cleaning process indicator (RPI) as a routine test device according to GPA. You can find suitable products in our online shop.

Request a quote

Non-binding quote for your facility

Briefly tell us the device type, number and make. We will get back to you personally and prepare a quote that suits your equipment.

  • Personal response from our specialists
  • Manufacturer-independent for all makes
  • Active throughout Switzerland
By submitting, you agree to the processing of your details in accordance with our privacy policy.